Mon–Fri 8 AM–7 PM · Sat–Sun 8 AM–4 PMIndependent Electrolux repair · Las Vegas Valley(725) 353-8500
Electrolux AppliancesRepair Service · Las Vegas

Error codes

Electrolux dryer error codes

$75 service call, applied toward an approved repair · 90-day labor warranty · Reviewed October 5, 2026

Electrolux dryers report two-character codes, shown with a leading E (E53, EF1, EF3). Only a few are displayed during normal use — most are stored. Electrolux tech tips have refined the meaning of some codes, notably E53.

Electrolux Error Code Finder

Electrolux 300–700 Series front-load dryers (ELFE electric / ELFG gas)

ELFE (electric) and ELFG (gas) model numbers; Balanced Dry / LuxCare Dry with capacitive moisture sensing on 500/600 Series.

  • These dryers control heat with two temperature sensors (NTC1 and NTC2) read by the main board, plus a thermostat and thermal limiter in the heat path.
  • F1 (ventilation blocked) troubleshooting starts with the lint filter and the exhaust run all the way to the wall before any part is replaced.
  • 500 and 600 Series dryers use a capacitive moisture-sensing assembly; 300 and 400 Series use conventional moisture-sensor bars.
  • On ELFG gas dryers, EF3 refers to no gas supply detected; the first check is that the gas supply to the dryer is turned on.
CodeMeaningDisplay
E34Capacitive moisture sensor reading outside its predefined range (500/600 Series)Stored (service mode)
E35Capacitive moisture sensor communication problem with the main board (500/600 Series)Stored (service mode)
E41Door opened at cycle startStored (service mode)
E42Door closed sensing errorStored (service mode)
E51Drum motor relay errorStored (service mode)
E52Drum motor start sensing errorStored (service mode)
E53Drum motor centrifugal switch error (see bulletins: usually heating-circuit wiring)Stored (service mode)
E54Drum motor sensing errorStored (service mode)
E61Heater relay errorStored (service mode)
E63Heater short errorStored (service mode)
E64Heater open errorStored (service mode)
E65Thermostat openStored (service mode)
E67Thermal/heater sensing error (dual-coil models)Stored (service mode)
E71Temperature sensor NTC1 openStored (service mode)
E72Temperature sensor NTC1 shortedStored (service mode)
E73Temperature sensor NTC2 openStored (service mode)
E74Temperature sensor NTC2 shortedStored (service mode)
E91User interface communication problem with the main boardStored (service mode)
E92User interface / main board protocol mismatchStored (service mode)
E93Machine configuration checksum errorShown on display
E94Cycle configuration checksum errorShown on display
E97Missing program in the cycle tableShown on display
E9CUser interface configuration checksum errorShown on display
E9EUser interface touch sensor not workingStored (service mode)
EH1 / EB1Power supply frequency out of rangeShown on display
EH2 / EB2Supply voltage too highShown on display
EH3 / EB3Supply voltage too lowShown on display
EH4 / EB4Line wiring error at the terminal blockShown on display
EHA / EBDLine-safe relay short circuitStored (service mode)
EHE / EBELine-safe errorStored (service mode)
EHF / EBFLine-safe sensing errorStored (service mode)
EF1Ventilation blockedShown on display
EF6Safety reset errorStored (service mode)
EF3No gas supply detected (gas models)Shown on display

Electrolux LuxCare front-load dryers (EFMG gas / EFME electric)

EFMG (gas) / EFME (electric) LuxCare Dry models.

  • For E53 on LuxCare gas dryers, the manufacturer notes the cause is almost never the main control or motor but a wiring or electrical issue in the heating circuit.
  • If items rest on the lint filter or the filter pops out, the manufacturer offers a newer sloped lint grill and filter kit for these front-load dryers.
  • Service flashes describe a heat-expansion ticking noise between the back panel or rear bulkhead and the heater on certain LuxCare dryers.
CodeMeaningDisplay
E34Capacitive moisture sensor reading outside its predefined range (500/600 Series)Stored (service mode)
E35Capacitive moisture sensor communication problem with the main board (500/600 Series)Stored (service mode)
E41Door opened at cycle startStored (service mode)
E42Door closed sensing errorStored (service mode)
E51Drum motor relay errorStored (service mode)
E52Drum motor start sensing errorStored (service mode)
E53Drum motor centrifugal switch error (see bulletins: usually heating-circuit wiring)Stored (service mode)
E54Drum motor sensing errorStored (service mode)
E61Heater relay errorStored (service mode)
E63Heater short errorStored (service mode)
E64Heater open errorStored (service mode)
E65Thermostat openStored (service mode)
E71Temperature sensor NTC1 openStored (service mode)
E72Temperature sensor NTC1 shortedStored (service mode)
E73Temperature sensor NTC2 openStored (service mode)
E74Temperature sensor NTC2 shortedStored (service mode)
E91User interface communication problem with the main boardStored (service mode)
E92User interface / main board protocol mismatchStored (service mode)
E93Machine configuration checksum errorShown on display
E94Cycle configuration checksum errorShown on display
E97Missing program in the cycle tableShown on display
E9CUser interface configuration checksum errorShown on display
E9EUser interface touch sensor not workingStored (service mode)
EH1 / EB1Power supply frequency out of rangeShown on display
EH2 / EB2Supply voltage too highShown on display
EH3 / EB3Supply voltage too lowShown on display
EH4 / EB4Line wiring error at the terminal blockShown on display
EHA / EBDLine-safe relay short circuitStored (service mode)
EHE / EBELine-safe errorStored (service mode)
EHF / EBFLine-safe sensing errorStored (service mode)
EF1Ventilation blockedShown on display
EF6Safety reset errorStored (service mode)
E36Capacitive sensor assembly / main board protocol mismatch (500/600 Series)Stored (service mode)
E67Heater sensing circuit failureStored (service mode)
EHdDisplayed when the dryer will not start and only beeps; checks focus on supply voltage and connector seating at the board and heating systemShown on display

Electrolux Laundry Tower (ELTE electric / ELTG gas)

ELTE (electric dryer) / ELTG (gas dryer) single-unit laundry towers with separate washer and dryer controls.

  • The Laundry Tower has separate washer and dryer controls, each with its own code list and its own last-error recall, so a code must be read together with which half displayed it.
  • On the Laundry Tower washer, E5H is the same as E5B (motor control under voltage).
  • For E53 on Laundry Tower dryers the manufacturer points to an open in the heating circuit between the terminal block and the heating relay (L2 side on electric, neutral side on gas), and notes it is almost never the main control or motor.
  • For a tapping noise on the Laundry Tower, the manufacturer checks that a felt pad under the dryer top panel is present and correctly placed.

Dryer section

CodeMeaningDisplay
E34Capacitive moisture sensor reading outside its predefined range (500/600 Series)Stored (service mode)
E35Capacitive moisture sensor communication problem with the main board (500/600 Series)Stored (service mode)
E41Door opened at cycle startStored (service mode)
E42Door closed sensing errorStored (service mode)
E51Drum motor relay errorStored (service mode)
E52Drum motor start sensing errorStored (service mode)
E53Drum motor centrifugal switch error (see bulletins: usually heating-circuit wiring)Stored (service mode)
E54Drum motor sensing errorStored (service mode)
E61Heater relay errorStored (service mode)
E63Heater short errorStored (service mode)
E64Heater open errorStored (service mode)
E65Thermostat openStored (service mode)
E67Thermal/heater sensing error (dual-coil models)Stored (service mode)
E71Temperature sensor NTC1 openStored (service mode)
E72Temperature sensor NTC1 shortedStored (service mode)
E73Temperature sensor NTC2 openStored (service mode)
E74Temperature sensor NTC2 shortedStored (service mode)
E91User interface communication problem with the main boardStored (service mode)
E92User interface / main board protocol mismatchStored (service mode)
E93Machine configuration checksum errorShown on display
E94Cycle configuration checksum errorShown on display
E97Missing program in the cycle tableShown on display
E9CUser interface configuration checksum errorShown on display
E9EUser interface touch sensor not workingStored (service mode)
EH1 / EB1Power supply frequency out of rangeShown on display
EH2 / EB2Supply voltage too highShown on display
EH3 / EB3Supply voltage too lowShown on display
EH4 / EB4Line wiring error at the terminal blockShown on display
EHA / EBDLine-safe relay short circuitStored (service mode)
EHE / EBELine-safe errorStored (service mode)
EHF / EBFLine-safe sensing errorStored (service mode)
EF1Ventilation blockedShown on display
EF6Safety reset errorStored (service mode)
EF3No gas error (gas models)Shown on display

Other Electrolux models

For these families we have not published a code table because the documentation we hold is not specific enough to state meanings reliably. Codes on these models depend on the model and control platform — call us with the code and model number.

  • Electrolux Wave-Touch and IQ-Touch front-load dryers (EIED / EIGD / EWED / EWGD / EIMED / EIMGD)

Reading a code safely

  • Write down the code exactly, including letters (E5B vs E58).
  • Note whether it appeared during a cycle or only after a reset.
  • Power-cycle once (unplug or switch the breaker off for a minute). If the same code returns, the condition is still present.
  • Do not repeatedly reset an appliance that shows heating, gas or electrical codes.

Online troubleshooting is preliminary guidance, not a diagnosis. Electrolux appliances use different control platforms, sensors and diagnostic logic depending on the model, and several failures can produce the same symptom — internal testing is often needed to identify the actual failed component.

Electrolux dryer repair in Las Vegas

Sources

Code meanings are summarized in our own words from Electrolux tech data sheets, service manuals and tech tips for each listed family. "Shown on display" and "Stored" follow the manufacturer's display-notification column where the document provides one.

Book an Electrolux technician

$75 service call · price approved before work · 90-day labor warranty · Mon–Fri 8 AM–7 PM · Sat–Sun 8 AM–4 PM